10. Evaluate and plot material curves¶
Evaluate S–N curve points with sn_curve. Request native figures
with plot_py_fatigue. The examples use illustrative material
parameters. Supply your calibrated parameters and units in real analyses.
Request format: "png" for an image or format: "echarts" for an
embedded HTML chart. Your client determines how it displays these results.
S–N curves¶
- “With S–N slope 3 and log10 intercept 12, calculate cycles to failure at stress ranges of 80, 100, and 200 MPa.”
- “For the same curve, calculate the stress ranges for one and ten million cycles.”
- “Set the endurance limit to one million cycles. Evaluate life at 20 and 200 MPa and explain the infinite-life result.”
- “Evaluate the piecewise curve with slopes 3 and 5, log10 intercepts 10.970 and 13.617, and endurance at 100 million cycles. Give ranges for 10,000 and 1,000,000 cycles.”
- “Plot the native S–N curve with slope 3 and log10 intercept 12 on log-log axes.”
- “Add measured pairs at 100,000 cycles and 220 MPa, and 1,000,000 cycles and 105 MPa. Keep the native S–N curve visible.”
- “Use the same data and generate an interactive S–N chart.”
- “Show the piecewise curve on semilog-x axes with its endurance limit.”
A direct plot call uses paired arrays for an overlay.
{
"request": {
"kind": "sn_curve",
"curve": {"slope": 3, "intercept": 12},
"cycles": [100000, 1000000],
"stress_ranges": [220, 105],
"scale": "loglog"
},
"format": "echarts"
}
Miner damage¶
- “Using the inline stress-history example, calculate Miner damage and show the native contributions by stress range.”
- “Show the native Miner damage histogram for the same history and curve.”
- “Use the local
stress-history.csvinput and an S–N slope of 3 with log10 intercept 12. Export every contribution and return the plot as PNG.” - “Use three counted stress ranges of 50, 80, and 120 MPa with weights 10, 4, and 0.5, respectively. Calculate and plot their Miner contributions.”
- “Use the combined CycleCount example and compare Miner damage for stress concentration factors of 1 and 1.25.”
Paris, Walker, and NASGRO curves¶
Use MPa·√mm for stress intensity and mm/cycle for growth rate. Paris
and Walker intercept values are coefficients in the selected unit
system. S–N intercepts use the log10 convention.
- “Use the native Paris curve with slope 3, coefficient
1e-12, threshold 25 and critical intensity 500. Return a log-log plot.” - “Plot the same fit using the Walker law with load ratio 0.3 and Walker exponent 0.5.”
- “Overlay observations of
1e-6at 100 and8e-6at 200 on the native Paris curve. Show the original fit and both observations.” - “Plot the NASGRO law from the SC07 example in its long-crack limit.”
- “For that NASGRO curve, set the crack length to 4 mm and minimum intensity to 20 MPa·√mm. Sweep up to 400 MPa·√mm.”
- “For the same curve and length, sample exactly 75, 150, and 300 MPa·√mm. Return the interactive plot on semilog-y axes.”