2. Rainflow and residuals

Rainflow counting converts an ordered stress record into a spectrum that can be used in a fatigue analysis. The residual turning points keep track of excursions that may continue in the next window.

Rainflow

Rainflow counting extracts stress ranges, means and cycle counts from a stress history. The v3 ASTM three-point implementation runs in Rust. CycleCount.from_timeseries also accepts rainflow_method="fourpoint". Residual half-cycles carry unresolved excursions at the ends of the record. Keep those residuals when combining windows. For measured input, CycleCount.from_sep005 converts supported stress units to MPa. For a pyExSi signal, supply the sampling frequency and stress unit explicitly. See cycle counting and signal input.

Initially, rainflow turns the load history into a sequence of time (t) ordered reversals. Reversals are the local minima and maxima where the load first derivative changes sign. The function counts cycles by considering a moving reference point of the sequence, Z, and a moving ordered three-point subset - t(subset) ≥ t(Z) - with these characteristics:

  • The first and second points are collectively called Y.

  • The second and third points are collectively called X.

  • | In both X and Y, the points are sorted from earlier to later in | time, but are not necessarily consecutive in the reversal sequence.

The range of X, denoted by r(X), is the absolute value of the difference between the amplitude of the first point and the amplitude of the second point. The definition of r(Y) is analogous. The rainflow algorithm is as follows (the rainflow chart).

---
config:
  fontFamily: IBM Plex Sans
  themeVariables:
    fontSize: 0.75rem
  flowchart:
    useMaxWidth: false
    wrappingWidth: 175
    nodeSpacing: 25
    rankSpacing: 38
---
flowchart TD
    accTitle: ASTM three-point rainflow counting
    accDescr: Add reversals to a pending stack, compare the two latest ranges and count closed or residual cycles.
    A["Extract reversals from the stress history"] --> B{"More reversals?"}
    B -->|Yes| C["Add the next reversal"]
    C --> D{"At least three pending reversals?"}
    D -->|No| B
    D -->|Yes| E{"Is the latest range X at least as large as Y?"}
    E -->|No| B
    E -->|Yes| F{"Does Y start at the oldest pending reversal?"}
    F -->|Yes| H["Count Y as a half-cycle and remove its first reversal"]
    F -->|No| I["Count Y as a full cycle and remove both its reversals"]
    H --> D
    I --> D
    B -->|No| J["Count each remaining range as a half-cycle"]

    class A flowInput
    class B,D,E,F flowDecision
    class H,I,J flowResult
    classDef flowInput fill:#dcecf8,stroke:#567fa0,color:#18376a
    classDef flowDecision fill:#f5e7ce,stroke:#98723a,color:#452f17
    classDef flowResult fill:#d9eade,stroke:#548167,color:#1b4735

At the end, the function collects the different cycles and half-cycles and tabulates their ranges, their means, and the points at which they start and end. This information can then be used to produce a histogram of cycles.

Example

The following example shows how to use the rainflow algorithm to cycle-count the signal given in the image here below.

Rainflow example

Z Reversals Out of data? < 3 reversals? Y X r(X) < r(Y)? Y includes Z? Actions
O O, A, B No No OA AB No Yes
Show
  1. Count OA as ½.
  2. Discard O.
  3. Set Z to A.
A A, B No Yes — — — —
ShowRead C.
A A, B, C No No AB BC Yes —
ShowRead D
A A, B, C, D No No BC CD Yes —
ShowRead E.
A A, B, C, D, E No No CD DE No No
Show
  1. Count CD as 1.
  2. Discard C and D.
A A, B, E, No No AB BE Yes —
ShowRead F.
A A, B, E, F No No BE EF Yes —
ShowRead G.
A A, B, E, F, G No No EF FG No No
Show
  1. Count EF as 1.
  2. Discard E and F.
A A, B, G No No AB BG No Yes
Show
  1. Count AB as ½.
  2. Discard A.
  3. Set Z to B.
B B, G Yes — — — — —
ShowCount BG as ½.

LFFD

In continuously monitored structures, keeping a count per recording window makes long histories easier to store and process. An excursion that crosses a window boundary may appear as multiple half-cycles when the windows are counted independently. The remaining turning points preserve the order needed to recover such excursions.

The method described by Marsh and coauthors uses the saved spectra and ordered residuals. For example, count each window of a bending-moment record and store its full-cycle histogram together with the residual turning points. If the table also includes half-cycles, set those rows aside during recovery. Concatenate the residual sequences in acquisition order, count them again, then merge the recounted rows with the saved full cycles. Keep any residuals left from this second pass for future aggregation.

This lets you combine long runs or choose different analysis windows using small retained histories. It still depends on continuous data. If acquisition stopped between windows, the residuals cannot recover the loading that went unmeasured.

---
config:
  fontFamily: IBM Plex Sans
  themeVariables:
    fontSize: 0.75rem
  flowchart:
    useMaxWidth: false
    wrappingWidth: 175
    nodeSpacing: 25
    rankSpacing: 38
---
flowchart TD
    accTitle: Recover low-frequency cycles from segmented load data
    accDescr: Store each window's histogram and residual reversals, then count the combined residuals and merge with the full cycles.
    S["Read the next signal segment"] --> C{"Cycle count already stored?"}
    C -->|No| P["Process the signal and count cycles"]
    P --> H["Store the histogram and ordered residual reversals"]
    C -->|Yes| W{"More segments in the time window?"}
    H --> W
    W -->|Yes| S
    W -->|No| F["Remove half-cycles and merge the full-cycle histograms"]
    W -->|No| R["Concatenate residual reversals in time order"]
    R --> N["Count cycles in the combined residual sequence"]
    F --> M["Merge the full cycles and recounted residual cycles"]
    N --> M
    M --> T["Store the combined histogram and remaining residuals"]

    class S flowInput
    class C,W flowDecision
    class H,M,T flowResult
    classDef flowInput fill:#dcecf8,stroke:#567fa0,color:#18376a
    classDef flowDecision fill:#f5e7ce,stroke:#98723a,color:#452f17
    classDef flowResult fill:#d9eade,stroke:#548167,color:#1b4735

For a worked example, see the MCP LFFD walkthrough or the cycle-count aggregation notebook.

Fatigue loading in wind turbines

NASA's experimental multi-megawatt wind turbines of the 1970s and 1980s included steel tube towers. Experience with early designs helped establish fatigue as a design requirement because the loads on a turbine vary over its lifetime.

For offshore support structures, repeated loads and the corrosive environment also affect inspection and maintenance. Structural health monitoring captures histories that can inform fatigue-life estimates and the timing of inspections. The figure below shows changes in the energy mix during the expansion of wind power in the EU-27.

EU-27 electricity production by source, 2000–2020
Figure 1. Percentage share of energy production in EU-27 countries from 2000 to 2020. Years 2019 and 2020 have been extrapolated by EMBER. Data from 2021. 2000 to 2018 are available from EUROSTAT.

Stress–strain hysteresis loops show how a material responds to nested loading excursions. Cycle counting uses the ordered peaks and valleys to represent those excursions by their ranges and weights. By convention, tensile stress is positive and compressive stress is negative.

Figure 2. Stress-strain hysteresis loops for a time series

Figure 3. The fatigue cycle

Changes in wind and rotor thrust can create slow excursions. Waves can add faster cycles. The two effects can occur within the same record.

Figure 4. Schematics of the loads acting on an offshore wind turbine